Call Toll Free: 800-666-9101Company Profile | Contact / Request Quote | Email
HomeFlow Switches Level Switches Flow & Level IndicatorsProduct IndexCapabilitiesTerms & ConditionsCompare & Specify Products Now! Start Here Thomas Products designs and manufactures hundreds of standard flow and level
switches, as well as water flow gages, liquid level gauges, flow gages,
water level controls, liquid level controls and flow controls.
Registered UsersSign In
 
View CartView RFQ'sExpress Ordering
 Shopping Cart  0 Items 
 Request for Quote  0 Items 
All Categories > Level Switch > Pancake > Pancake, Plastic - 3800 Series Level Switch > Item # 43426  
Request Information

Item # 43426, Pancake, Plastic - 3800 Series Level Switch

List Price $88.00

    Download PDF Download PDF  
    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

Pancake, Plastic - 3800 Series Level Switch

larger image
  • Double wall tanks.
  • Containment piping.
  • Ideal for leak detection systems.
  • Operates down to -40°F.
  • Positive signals.
  • Very economical.
  • Not affected by translucent films.
  • Can be immersed continuously in any media compatible with wetted parts.
  • No special controls necessary.
  • No excitation voltage necessary.
  • No false indications.




Specifications · Notes

Specifications

Floats

PVC

Wire

22 AWG UL 2464 25" Long

Reed Switches (Non UL Recognized Units)

10 VA SPST

Operating Temperature

-40o to 140oF Max

Operating Pressure

50 psi

Housing Material

PVC

Mounting Attitude

Horizontal

Application

Lays at the bottom of tank or double wall containment system.

Notes

1 & 2


Notes
Notes:
  1. Specific gravity .7 minimum.
  2. Operates in 5/8"envelope. Actuates in approximately 1/4" of water level.
  3. Wetted parts: stainless steel, PVC, hysol epoxy, and cunife magnet.
  4. Use in flammable environments. Should only be used with an intrinsically safe barrier to make the sensor safe not posing a hazard.
  5. Model 3800 switch logic is the same N.C. (normally closed) tank dry condition in either side unit is installed.
  6. Switch logic N.C. (normally closed) tank dry. Switch opens on increasing level.